JOAP: HITACHI - Transport Applications - 2020

*Tandem(multiple) use model is available for vertical type only. *Heat pump model for cold district specification is available on request. General Data For Train Use AC Inverter Fixed speed Model G501DLV-64DTP G501DLV-64ATP CA47TLA-D2PE1 CA56TLA-D2PE1 CA64TLA-D1PE1 CA80TLA-D1PE1 Horizontal / Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Nominal Rating (HP) 5 5 3 3.5 4 5 Displacement cm 3 /rev. 64 64 47 56 64 80 Primary power supply 3 phase voltage V 380-415 200-220 - - - - Speed Range Hz 60-100 60-100 - - - - Power supply Phase φ - - 3 3 3 3 Voltage V - - 380-415 380-415 380-415/460 380-415/460 Frequency Hz - - 50 50 50/60 50/60 Rated Performance Cooling Capacity kW 13.10 13.10 8.00 9.50 10.90 13.50 BTU/h 44,699 44,699 27,297 32,415 37,192 46,064 Power Input kW 4.70 4.70 2.90 3.40 3.90 4.90 COP W/W 2.79 2.79 2.76 2.79 2.79 2.76 Test Condition B B B B B B Chamber size (φ) 160 160 160 160 160 160 Weight (including oil) kg 37 37 35 35 35 35 lb 81.59 81.59 77.18 77.18 77.18 77.18 Certificate No No CE CE CE CE Fixed speed Model G500DL-80HTC G600DL-90HTP GA120TLA-D2PE1 G700GL-120CTP G750EL-128DTC G750EL-128CTP Horizontal / Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Nominal Rating (HP) 5 6 7 7 7.5 7.5 Displacement cm 3 /rev. 80 90 120 120 128 128 Power supply Phase φ 3 3 3 3 3 3 Voltage V 230 230 380-415 380-400 380-415 380-400 Frequency Hz 60 60 50 60 50 60 Rated Performance Cooling Capacity kW 16.30 18.30 20.80 25.10 22.10 25.90 BTU/h 55,618 62,442 70,973 85,645 75,408 88,374 Power Input kW 6.00 6.80 6.80 8.30 7.20 8.60 COP W/W 2.72 2.69 3.06 3.02 3.07 3.01 Test Condition B B B B B B Chamber size (φ) 160 160 190 190 235 235 Weight (including oil) kg 35 35 64 64 89 89 lb 77.18 77.18 141.12 141.12 196.25 196.25 Certificate CE No CE No CE No Japan production R407C A Evaporating temp 7.2 °C Condensing temp 54.4 °C Suction gas temperature 18.3 °C Expansion valve inlet temp 46.1 °C Ambient temperature 35.0 °C Frequency 50 Hz Rotation speed (AC/DC inv) 60 Hz Compressor cooling - B Evaporating temp : 7.2 C Condensing temp : 54.4 C Suction gas temperature 18.3 C Expansion valbe inlet temp 43.9 C Ambient temperature : 35.0 C Frequency: 50 Hz Rotationspeed:(AC/DCinv) 60 Hz Compressor cooling: - Testing condition Fixed speed Model CA47TLA-D2PE3 CA56TLA-D2PE3 GA120TLA-D2PE3 GA120TLC-C3PC3 Horizontal / Vertical Horizontal Horizontal Horizontal Horizontal Nominal Rating (HP) 2 2.5 5 5 Displacement cm 3 /rev. 47 56 120 120 Power supply Phase φ 3 3 3 3 Voltage V 380-415 380-415 380-415 380-400 Frequency Hz 50 50 50 60 Rated Performance Cooling Capacity kW 5.50 6.50 14.50 17.00 BTU/h 18,767 22,179 49,476 58,006 Power Input kW 1.90 2.20 4.70 5.50 COP W/W 2.89 2.95 3.09 3.09 Test Condition A A A A Chamber size (φ) 160 160 190 190 Weight (including oil) kg 35 35 64 64 lb 77.18 77.18 141.12 141.12 Certificate CE CE CE No R134a

RkJQdWJsaXNoZXIy NzAwNg==